EQ8096 M-CMTS System Test Specification
10.3.1 System Setup
A tester must perform the following set up when first installing the EQAM
• The EQ8096 must have the DTI client card installed. The DTI client can be
either factory fitted or field upgradeable. If necessary, please refer to Chapter 9
of the EQ8096 Reference Guide for instructions regarding this field upgrade
process.
• M-CMTS license enabled (please contact Ericsson Customer Support)
• Power up the EQAM
• After the EQAM has booted note the IP address/mask on the front panel and set
up a PC to be in the same subnet.
• If you wish to change this IP Address/subnet mask you can do this via the front
panel or alternatively connect the EQAM via a web client, You will be presented
with the following Web GUI, Figure 10.2:
Figure 10.2 Web GUI Home Page
Note: If the DTI client card is not present the “DEPI Configuration” and “DEPI
Statistics” tab will not be present and the DTI card information “DTI Client
Locked: Yes” and “DTI Timestamp: XXXXXXX” under status will not be
present.
10.3.2 M-CMTS Session Setup
The M-CMTS EQAM sessions are configured using the DEPI Configuration WEB
GUI Page.