B.10 Cable Types
The signal cable types (or similar) in Table B.17 are those recommended by
Ericsson in order to maintain product EMC compliance.
Table B.17 Suitable Signal Cable Types
Signal Type Connector Cable
Video Cables
BNC (Twin
screened coaxial)
Canford 1/3 PSF (type 2 Video cable)
ASI Inputs
BNC (Twin
screened coaxial)
Canford 1/3 PSF (type 2 Video cable)
ASI Outputs
BNC (Twin
screened coaxial)
Canford 1/3 PSF (type 2 Video cable)
Relay 9-Way, D-Type Belden 8162 CM2PR24
RS-232/Data 9-Way, D-Type Belden 8162 CM2PR24
RS-232/Remote 9-Way, D-Type Belden 8162 CM2PR24
Ethernet IP
input/output
RJ-45
CAT5E 1 GHz data cable S and F
twisted pair