The data Ethernet ports Ge 1 and Ge 2 are paired together, as are Ge 3 and Ge 4. Each port of a pair transmits the same multicasts.
If the IP address, or subnet mask of a secondary port is set to 0.0.0.0, then it will be assumed that it is operating in a mirrored
redundancy mode with the primary port, and therefore has the same IP address and subnet mask.
Data Input
The unit has four Ethernet ports for data output and will respond to ARPs, pings and Reflex PCR exchange messages for statistical
multiplexing.
The input of other data is NOT supported.
Data Output
The unit can generate one or more output transport streams from the components produced by the option cards fitted. The output
transport stream packets are encapsulated in IP packets prior to being transmitted via the Ethernet Data ports. The base chassis
does not provide any other interface by which to output a transport stream.
Default MAC Address aa:bb:cc:dd:ee:ff
Gex port’s MAC address (This cannot
be changed by the user)
Read only parameter
Link Status
Link Up (1000) Link up and link speed 1000 Mbps
Read only parameter
Link Up (100) Link up and link speed 100 Mbps
Link Down Link Down
Link Up Time
days : hours : mins :
secs
The length of time that the link has
been up. If the link goes down this
value is reset to 0
Read only parameter
TX Packets Number of IP packets transmitted Read only parameter
RX Packets Number of IP packets received Read only parameter
IP Address aaa.bbb.ccc.ddd IP address of the control port
Subnet Mask
0.0.0.0 [default]
aaa.bbb.ccc.ddd
Subnet mask for the control port
Default Gateway
0.0.0.0 [default] No defined gateway
aaa.bbb.ccc.ddd
Gateway address for packets outside
the defined subnet
© Ericsson AB 2011. All rights reserved