Ericsson RX8320 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Sítě Ericsson RX8320. Ericsson RX8320 User's Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - RX8320 ATSC Broadcast Receive

RX8320 ATSC Broadcast ReceiverSoftware Version 4.3.2 USER GUIDEEN/LZT 790 0008/2 R1A

Strany 2

Quick Start Guide: Connect-Power-Configure 3 Quick Start Guide: Connect-Power-Configure 3.1 Connecting the Receiver The following points should b

Strany 3 - Contents

Quick Start Guide: Connect-Power-Configure 4. During initialization, confirm that the Status LED is on and all Up, Down, Left, Right, Edit and Save

Strany 4

Quick Start Guide: Connect-Power-Configure • The unit will automatically decode the first video component that it finds within the selected service

Strany 5 - 1 Introduction

Quick Start Guide: Connect-Power-Configure and Maximum CAM Components Per Service dialog boxes. The user should refer to the CAM vendor for CAM compa

Strany 6 - Introduction

Front Panel Control 4 Front Panel Control 4.1 Introduction The Front Panel display and keypad may be used to configure, control and monitor the re

Strany 7 - 2 Installing the Equipment

Front Panel Control 4.3.2 LCD A 2-line x 40-character back-lit dot-matrix Liquid Crystal Display (LCD) displays various menus and settings. The menu

Strany 8 - 2.4 Rear Panel Connectors

Front Panel Control 4.4 Front Panel Menus An overview of the available Front Panel menus is shown below. The menus and settings available will vary

Strany 9 - Warning!

Front Panel Control 4.4.1 Menu Structure The Front Panel menus and sub-menus, available on the LCD, provide the configuration parameters that may be

Strany 10 - 3.2 Powering the Receiver

Front Panel Control • Output Menu - Provides sub-menus for viewing/configuring the receiver output parameters. - Output Selection - Enables select

Strany 11 - 3.3 Configuring the Inputs

Web Browser Control 5 Web Browser Control 5.1 Introduction A personal computer (PC) running a Web Browser can be used to configure, control and mon

Strany 12 - 12 (36)

RX8320 ATSC Broadcast Receiver Copyright © Copyright Ericsson AB 2011. All rights reserved. Disclaimer No part of this document may be reproduced i

Strany 13

Web Browser Control Unit Model Number and Name About button Header Function Tabs Navigation Path Toolbar Main Web Page Results Frame Figure 4 Web

Strany 14 - 4 Front Panel Control

Web Browser Control web page. When you switch between tabs, the browser remembers the path for each tab. • Navigation Path – The web pages are organ

Strany 15 - 4.3.3 Arrow Pushbuttons

Web Browser Control 5.3 Web Pages 5.3.1 Status This web page shows a number of top-level parameters indicating the current status of the receiver.

Strany 16 - Boot Screen

Web Browser Control Figure 7 Device Info Web Page This page also provides buttons to the following further web pages: • Build – provides details

Strany 17 - 4.4.1 Menu Structure

Web Browser Control 5.3.3 Alarms The Alarms web page provides access to the alarms settings for the receiver. The contents of this page are composed

Strany 18 - 18 (36)

Web Browser Control Figure 8 Alarms Web Page 5.3.4 Customization Web Page The Customization web page provides access to the list of licenses enable

Strany 19 - 5 Web Browser Control

Web Browser Control Figure 10 CA Web Page 5.3.6 Input The Input Web Page provides access to the parameters of the various inputs to the receiver.

Strany 20 - 20 (36)

Web Browser Control Figure 11 Input Web Page (8VSB Input Card fitted) 5.3.7 Service Plus The Service Plus web page provides access to the various

Strany 21 - 5.2.2 Viewing the Web Pages

Web Browser Control • Splice - gives access to the splice operation parameters. • DVB Subtitles - gives access to the Digital Video Broadcasting (

Strany 22 - 5.3 Web Pages

Web Browser Control 5.3.9 Output The Output web page provides access to the output feed parameters of the receiver. Figure 14 Output Web Page 5.

Strany 23

Contents Contents 1 Introduction... 5 1.1 Who Should Use

Strany 24 - 5.3.3 Alarms

Web Browser Control Figure 15 Download Web Page 5.3.11 SNMP This page gives access to the Simple Network Management Protocol (SNMP) parameters for

Strany 25 - 5.3.5 CA

Web Browser Control Figure 17 Presets Web Page 5.3.13 Save/Load The Save/Load web page provides a range of configuration download and upload facil

Strany 26 - 5.3.6 Input

Web Browser Control Figure 18 Save/Load Web Page 5.3.14 Help The Help web page gives access to a Web Interface User Guide which provides a brief

Strany 27 - 5.3.8 Decode

Equipment Packaging 6 Equipment Packaging 6.1 Packaging Statement The outer carton and any cardboard inserts are made from 82% recycled material an

Strany 28 - Figure 13 Decode Web Page

Materials Declarations 7 Materials Declarations 7.1 Overview Ericsson products are designed and manufactured in keeping with good environmental pr

Strany 29 - 5.3.10 Download

Disposal of this Equipment 8 Disposal of this Equipment 8.1 General Dispose of this equipment safely at the end of its life. Local codes and/or env

Strany 30 - 5.3.12 Presets

Recycling EN/LZT 790 0008/2 R1A 2011-03-30 36 (36) 9 Recycling Ericsson SA TV Recycling has a process facility that enables customers to retu

Strany 31 - 5.3.13 Save/Load

Contents EN/LZT 790 0008/2 R1A 2011-03-30 4 (36) List of Figures Figure 1 Rear Panel Connectors...

Strany 32 - 5.3.14 Help

Introduction 1 Introduction 1.1 Who Should Use this User Guide? This User Guide is written for operators/users of the RX8320 ATSC Broadcast Receive

Strany 33 - 6 Equipment Packaging

Introduction Table 2 RX8320 Hardware Options Marketing Code Price Object Number Supply Object Number Description RX8XXX/CABLE/XLR FAZ 101 0108/24

Strany 34 - 7 Materials Declarations

Installing the Equipment 2 Installing the Equipment 2.1 Introduction For best performance and reliability follow the instructions for site requirem

Strany 35 - 8.2 For the European Union

Installing the Equipment Warning! The Technical Earth is not a Protective earth for electric shock protection. This unit must be correctly earthed t

Strany 36 - 9 Recycling

Installing the Equipment ) Type of Connector Description ALARM 9-way male D-type connector for alarm signal output. AC POWER IEC100-120 V AC / 2

Komentáře k této Příručce

Žádné komentáře