RX8200 Advanced Modular ReceiverSoftware Version 4.3.2 USER GUIDEEN/LZT 790 0009 R1A
Installing the Equipment Warning! The Technical Earth is not a Protective earth for electric shock protection. This unit must be correctly earthed t
Installing the Equipment ) Type of Connector Description ASI/SD-SDI/HD-SDI OUT 1 , 2 & 3 75 Ω BNC connector for ASI or SDI (user selectable) out
Quick Start Guide: Connect-Power-Configure 3 Quick Start Guide: Connect-Power-Configure 3.1 Connecting the Receiver The following points should b
Quick Start Guide: Connect-Power-Configure 2. Switch on the AC power supply to the unit at the wall or rack outlet. Note: The RX8200 Receiver does
Quick Start Guide: Connect-Power-Configure 8. Set the set the LNB power output level A description of each of these User Settings can be found in t
Quick Start Guide: Connect-Power-Configure 9. Set up Sync Count to Lock/Sync Miss Sample Size 10. Set up Sync Miss Limit. A description of each of t
Quick Start Guide: Connect-Power-Configure • The unit will automatically decode the first two audio components that it finds within the selected se
Front Panel Control 4 Front Panel Control 4.1 Introduction The Front Panel display and keypad may be used to configure, control and monitor the rec
Front Panel Control 4.3.2 LCD A 2-line x 40-character back-lit dot-matrix Liquid Crystal Display (LCD) displays various menus and settings. The men
Front Panel Control 4.4 Front Panel Menus An overview of the available Front Panel menus is shown below. The menus and settings available will vary
RX8200 Advanced Modular Receiver Copyright © Copyright Ericsson AB 2011. All rights reserved. Disclaimer No part of this document may be reproduced
Front Panel Control — 2.2.1 Status 2.2.1.1 Lock Status 2.2.1.2 Error Ratio/Signal Level 2.2.1.3 Modulation/FEC Rate 2.2.1.4 Standard/Spectral
Front Panel Control 4.4.1 Menu Structure The Front Panel menus and sub-menus, available on the LCD, provide the configuration parameters that may be
Front Panel Control - Director – Enables configuration of Director Conditional Access parameters, such as: ID numbers, download status and the faci
Web Browser Control 5 Web Browser Control 5.1 Introduction A personal computer (PC) running a Web Browser can be used to configure, control and mon
Web Browser Control Unit Model Number and Name About button Header Function Tabs Navigation Path Toolbar Main Web Page Results Frame Figure 5 Web
Web Browser Control web page. When you switch between tabs, the browser remembers the path for each tab. • Navigation Path – The web pages are organ
Web Browser Control 5.3 Web Pages 5.3.1 Status This web page shows a number of top-level parameters indicating the current status of the receiver.
Web Browser Control Figure 8 Device Info Web Page This page also provides buttons to the following further web pages: • Build – provides details
Web Browser Control 5.3.3 Alarms The Alarms web page provides access to the alarms settings for the receiver. The contents of this page are composed
Web Browser Control Figure 9 Alarms Web Page 5.3.4 Customization Web Page The Customization web page provides access to the list of licenses enable
Contents Contents 1 Introduction... 5 1.1 Who Should Use
Web Browser Control • RAS - allows the user to select Digital Satellite News Gathering (DSNG) or Fixed Key mode and input a 7-digit DSNG key. Figu
Web Browser Control Figure 12 Input Web Page (Satellite Input Card fitted) Click on the Satellite Input button on the Input page to display a furth
Web Browser Control If the I/P Input Card is fitted, the following web page is displayed. Figure 14 Input Web Page (IP Card fitted) Click on the I
Web Browser Control Figure 15 Input > IP Input Sub Page (IP Card fitted) If the G.703 Input Card is fitted, the following web page is displayed
Web Browser Control Click on the G703 Input button on the Input page to display a further sub page. Figure 17 Input > G.703 Input Sub Page (G.7
Web Browser Control • VBI-VANC - gives access to Vertical Blanking Interval-Vertical Ancillary Data Space (VBI-VANC) parameters. • Splice - gives a
Web Browser Control 5.3.9 Output The Output web page provides access to the output feed parameters of the receiver. Figure 20 Output Web Page 5
Web Browser Control Figure 21 Download Web Page 5.3.11 SNMP This page gives access to the Simple Network Management Protocol (SNMP) parameters for
Web Browser Control Figure 23 Presets Web Page 5.3.13 Save/Load The Save/Load web page provides a range of configuration download and upload faci
Web Browser Control Figure 24 Save/Load Web Page 5.3.14 Help The Help web page gives access to a Web Interface User Guide which provides a brief d
Contents EN/LZT 790 0009 R1A 2011-03-30 4 (44) List of Figures Figure 1 Rear Panel Connectors...
Equipment Packaging 6 Equipment Packaging 6.1 Packaging Statement The outer carton and any cardboard inserts are made from 82% recycled material a
Materials Declarations 7 Materials Declarations 7.1 Overview Ericsson products are designed and manufactured in keeping with good environmental pra
Disposal of this Equipment 8 Disposal of this Equipment 8.1 General Dispose of this equipment safely at the end of its life. Local codes and/or en
Recycling 9 Recycling Ericsson SA TV Recycling has a process facility that enables customers to return Old and End-of-Life Products for recycling if
Recycling EN/LZT 790 0009 R1A 2011-03-30 44 (44)
Introduction 1 Introduction 1.1 Who Should Use this User Guide? This User Guide is written for operators/users of the RX8200 Advanced Modular Recei
Introduction Table 2 RX8200 Hardware Options Marketing Code Price Object Number Supply Object Number Description RX8200/HWO/DVBS2 FAZ 101 0113/5
Introduction Marketing Code Price Object Number Supply Object Number Description RX8200/SWO/MP2/MP4/SD/HD FAZ 101 0113/41 FAT 102 0156 MPEG-2 &
Introduction Marketing Code Price Object Number Supply Object Number Description 1080i or 720p) RX8200/SWO/XCONV FAZ 101 0113/55 FAT 102 0175 Cr
Installing the Equipment 2 Installing the Equipment 2.1 Introduction For best performance and reliability follow the instructions for site requirem